Skip to product information
1 of 2

SKU:EE800-H1-01A

Implant Surgical Bur and Prosthetic Driver Kit

Implant Surgical Bur and Prosthetic Driver Kit

Regular price $1,388.00 USD
Regular price Sale price $1,388.00 USD
Sale Sold out
Shipping calculated at checkout.
Quantity
Guaranteed Safe & Secure Checkout
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

  • Free Global Shipping Over $50
  • 30 Days Money-back Guarantee
  • Secure Shop Payment

This 40-piece dental implant instrument kit combines surgical burs, bone preparation drills, trephine drills, tissue punches, positioning rings, prosthetic screwdrivers, a manual implant wrench and an adapter in one organized metal instrument case.
The kit is intended as a multi-purpose auxiliary instrument set for dental implant surgery, bone contouring, bone harvesting, soft-tissue access and implant prosthetic screw handling. It includes six driver interfaces in both short and long configurations for working in different intraoral spaces.

Features

  • Complete 40-piece instrument configuration
  • 12 implant screwdrivers in short and long versions
  • Six different driver interface types
  • 16 surgical burs and bone preparation drills
  • Three trephine drills in Ø3.5, Ø5.0 and Ø7.0 mm
  • Two soft tissue punches in Ø4.5 and Ø5.0 mm
  • Five positioning rings from 6 to 14 mm
  • Includes a manual implant wrench and driver adapter
  • Clearly marked positions for easier instrument organization
  • Supplied in a dedicated metal instrument case

What’s Included

Implant Screwdrivers

The kit contains six driver interfaces, with one short and one long version of each.
Product Code Driver Type Configuration
821-101S Ø1.0 mm Short
821-102S Ø1.2 mm Short
821-103S Ø1.27 mm Short
821-104S Ø1.4 mm Short
821-105S NOB Type Short
821-106S ITI Type Short
821-101L Ø1.0 mm Long
821-102L Ø1.2 mm Long
821-103L Ø1.27 mm Long
821-104L Ø1.4 mm Long
821-105L NOB Type Long
821-106L ITI Type Long

The short drivers are suitable for areas with limited working space, while the long drivers provide additional reach where required.

Implant Screwdrivers

Surgical Burs and Drills

Product Code Instrument Specification
822-429C Lateral Window Bur Ø6.5 / Ø8.0 mm
822-104A Positioning Drill Ø2.0 mm
822-101A Triangular Bur No. 1
822-416A Round Bur Ø3.1 mm
822-412A Positioning Drill Ø1.4 mm
822-501A Twist Drill Ø1.5 / Ø2.3 mm
822-502A Twist Drill Ø1.7 / Ø2.6 mm
822-503A Pilot/Reamer Drill Ø1.5 / Ø2.2 mm
822-702A Pilot/Reamer Drill Ø2.2 mm
822-417C Round Bur Ø3.5 mm
822-301A Pineapple Bur Ø3.5 mm
822-303A Pineapple Bur Ø7.0 mm
822-603A Wheel Bur Ø6.0 mm
822-201A Disc Bur Ø7.0 mm
822-203A Disc Bur Ø11.0 mm
822-306A Pineapple Bur

Ø6.0 mm

Surgical Burs and Drills

 

Bur Functions

  • Positioning and pilot drills: Used for initial positioning and preliminary site preparation.
  • Twist drills: Used for controlled drilling according to the selected surgical protocol.
  • Round burs: Used for localized bone preparation and contouring.
  • Pineapple burs: Used for ridge contouring and smoothing irregular bone surfaces.
  • Wheel and disc burs: Used for bone cutting, sectioning and ridge-related procedures.
  • Lateral window bur: Intended for lateral sinus window preparation.

Trephine Drills

Product Code Diameter
818-206A Ø3.5 mm
818-203A Ø5.0 mm
818-107 Ø7.0 mm

The three trephine sizes provide options for circular bone cutting and autogenous bone harvesting according to the selected procedure.

Trephine Drills

Soft Tissue Punches

Product Code Diameter
813-405 Ø5.0 mm
813-404 Ø4.5 mm

Soft Tissue Punches

The tissue punches are intended for circular soft-tissue access during suitable implant procedures.

Positioning Rings

Product Code Size
823-111 6.0 mm
823-112 8.0 mm
823-113 10 mm
823-114 12 mm
823-115 14 mm

Positioning Rings

Wrench and Adapter

Product Code Instrument Quantity
820-101 Manual Dental Implant Wrench 1
821-000 Driver Adapter 1

The adapter connects the selected driver to the manual wrench configuration.

Wrench and Adapter

Implant Screwdriver Compatibility Guide

Driver Type Referenced Implant Systems
1.0 mm Ankylos
1.2 mm Osstem, 3i, Neobiotech, Datsing, DIO (Older System)
1.27 mm Dentium, BEGO, Astra Tech, KJ Meditech, Zimmer, MIS, Cortex, Adin, BioHorizons, Alpha-Bio Tec
1.4 mm ICX
NOB Nobel Biocare
ITI Straumann ITI, DIO (Newer System)

The compatibility information above is based on the manufacturer’s reference chart. Implant systems may use different screw interfaces across product generations and prosthetic components. Always verify the driver shape and dimensions required by the specific implant component before use.
Third-party brand names are used only to identify the referenced implant systems. This product is not manufactured, authorized or endorsed by those brands.

Applications

The included instruments are intended for auxiliary procedures involving:
  • Dental implant surgery
  • Initial positioning and pilot drilling
  • Bone contouring and ridge preparation
  • Bone cutting and sectioning
  • Lateral sinus window preparation
  • Autogenous bone harvesting
  • Soft-tissue punching around an implant site
  • Implant and prosthetic screw handling
Instrument selection and operating parameters must be determined by a qualified dental professional according to the intended procedure and the applicable implant system protocol.

Important Notes

  1. For professional dental use only.
  2. This is a multi-purpose auxiliary instrument kit, not a complete implant placement drilling system.
  3. It does not replace the original surgical kit or drilling sequence specified by the implant manufacturer.
  4. Confirm the driver shape and dimensions before engaging an implant or prosthetic screw.
  5. Select each bur according to the intended procedure and applicable surgical protocol.
  6. Recommended speed, irrigation, drilling sequence and working depth should be determined according to the specific instrument and clinical procedure.
  7. Do not use the manual wrench as a calibrated torque wrench unless its torque-control specification has been independently confirmed.
  8. Inspect all cutting instruments and driver tips before each use.
  9. Sterilization parameters should follow the manufacturer’s validated instructions.
  10. The instrument case configuration may be updated without changing the principal kit contents.
View full details