The Curved Tissue Suturing Forceps are designed to hold and stabilize soft tissue while the suture needle is passed through the small opening at the working tip.
During suturing, the clinician uses the curved tips to grasp and position the soft-tissue flap. The circular opening provides a defined passage for the suture needle, allowing the tissue to remain supported during needle insertion.
This instrument is intended for soft-tissue closure following dental implant placement, bone augmentation, and other oral surgical procedures.
Features
-
Hold the Tissue During Suturing
The curved working ends grasp and stabilize the soft tissue, helping maintain the intended tissue position while the suture is placed. -
Needle Guide Openings
A small circular opening at each tip allows the suture needle to pass through the held tissue without first releasing the forceps. -
Tissue Positioning and Needle Passage in One Instrument
The same instrument can be used to hold the tissue flap in position and provide an opening for needle passage during suturing. -
Curved Working Ends
The curved profile supports access to confined oral areas and allows the tissue to be approached from an angle. -
Spring-Handle Control
The tweezer-style spring handle provides direct opening and closing control through fingertip pressure. -
Fenestrated Handle
The openings along the handle reduce unnecessary instrument bulk and make the instrument easy to identify within a surgical setup.
Needle Guide Tip Design
Each curved working end features a small circular opening.
During suturing, the tips are used to grasp and stabilize the soft tissue. Once the tissue is held in the required position, the suture needle can be passed through the circular opening and the supported tissue.
This design allows the clinician to maintain tissue control during needle penetration without releasing and repositioning the tissue before the stitch is placed.
Specifications
| Specification | Details |
|---|---|
| Product Type | Tissue Suturing Forceps |
| Product Code | EE805-101 |
| Material | Stainless steel |
| Overall Length | 15 cm / 5.9 in |
| Working End | Curved |
| Tip Design | Circular Needle Guide Holes |
| Handle Type | Spring Handle |
| Handle Design | Fenestrated |
| Primary Function | Holding Soft Tissue During Needle Passage |
| Quantity | 1 Forceps |
Applications
- Soft-tissue suturing after dental implant placement
- Suturing following bone augmentation procedures
- Guided bone regeneration procedures
- Tissue-flap positioning and closure
- Wound-edge approximation
- Periodontal surgery
- Oral soft-tissue surgery
Important Notes
- Intended for use by trained dental and surgical professionals.
- Confirm that the selected suture needle can pass through the tip opening before use.
- Use the minimum pressure required to hold the soft tissue securely.
- Do not use the instrument to drive, bend, or clamp the surgical needle.
- Use an appropriate needle holder to control and advance the needle.
- Inspect the circular openings, tip alignment, and instrument condition before every procedure.
- Follow the healthcare facility’s validated cleaning, disinfection, and sterilization protocol.
FAQ

Collections
-
GBR Instruments
Professional GBR instruments and accessories, including tenting screws, mesh membranes, and bone...
-
Instruments
Dental instruments designed for diagnosis, clinical procedures, and daily practice across periodontal,...
-
implantology
Includes dental implants with their corresponding abutments and accessories, as well as...